Hager 4501 Rim Exit Device Fire Rated and Non-Rated Grade 1 Push Bar Style

Regular price $1,195.00

Shipping calculated at checkout.

Hager 4501 Rim Exit Devices are ideal for use in heavy duty commercial applications including office buildings, medical facilities, schools, and hospitality structures. The Hager 4501 Rim Exit Device is designed and engineered to provide a lifetime of superior performance on doors in heavy duty commercial applications. Properly applied and maintained Hager 4500 Series Exit Devices and Trim are backed by a manufacturers lifetime warranty, providing peace of mind from distributor to building owner. Hager 4501 Rim Exit devices are BHMA certified Grade 1 and meet Life Safety codes and Fire Safety requirements. The 4501 Rim exit device meets ANSI requirements to be listed as Severe Windstorm Components and are approved for High Velocity Hurricane Zone areas. Extruded aluminum construction, stainless steel push bar cover, die cast caps and covers, and dead locking stainless steel Pullman type latchbolts provide premium security and performance at value pricing.

  • ANSI/BHMA A156.3-2014 Grade 1
  • UL305 Listed for Panic Hardware
  • UL/cUL Listed for up to 3 hours for "A" label single doors
  • UL10C Positive Pressure Rated
  • UL10B Neutral Pressure Rated
  • Warnock Hersey listed for up to 3 hours with fire rated removable mullion
  • Complies with ANSI A117.1 for accessible buildings and facilities
  • Miami-Dade County, Florida NOA #17-1226.23, Exp. Aug. 16, 2022.

Covers:

  • Stainless steel, zinc


Cover Tube:

  • Aluminum


End Caps:

  • Standard end cap (zinc)


Door Width:

  • 36'' (914 mm) field sizeable to 30'' (762 mm) panic-rated door and 28" (711 mm) fire-rated door
  • 48'' (1219 mm) field sizeable to 36'' (914 mm) panic- or fire-rated door



Door Thickness:

  • 1-3/4" (44 mm) 


Stile Width:

  • 5-3/8" (137 mm) - Minimum stile width required for single doors and standard 5/8" (16 mm) stop
  • 4-7/8'' (124 mm) - Minimum stile width required for double door x surface vertical rod with double door strike
  • 5-3/4" (146 mm) - Minimum stile width required for double door and 2" (51 mm) mullion
  • 5" (127mm) - Minimum stile width required for double doors with a middle rail and a 2" mullion
  • All stile widths are measured from the door edge


Fasteners:

  • Wood and machine screws
  • Thru-bolts


Latchbolt:

  • 3/4" (19 mm) throw, pullman type with automatic dead-latching, stainless steel

Strikes:

  • Stainless steel with plated rollers - Included standard with panic devices
  • Solid stainless steel - Included standard with fire-rated devices
  • Surface applied to frame with slotted holes for easy adjustment

Dogging:

  • Hex key dogging standard on panic rated devices

Projection:

  • 3" (76 mm) in undogged position
  • 2-5/8" (67 mm) in dogged position

Notes:

  • Recommended to be used on appropriately reinforced doors
Available Lengths:
  • 36"
  • 48"
Hager 4501 rim exit devices are cut for 36” (914 mm) and 48” (1219 mm) wide doors. For other door widths, cut exit device to appropriate length. Recommended overall length of exit device is equal to the door width minus four inches

Available fire rated - F or non rated - O 

Trims sold separately 

Available Finishes:
  • US32D - Brushed Stainless Steel
  • US26D - Brushed Chrome
  • US26 - Bright Chrome
  • US10B - Oil Rubbed Bronze
  • US10 - Satin Bronze
  • US4 - Satin Brass
  • US3 - Bright Brass
  • BLK - Black